Low-voltage Switchgear
Low-voltage Switchgear

IEC 61439 / IEC 60439 & GB 7251.1 compliant switchgears for 50/60 Hz networks up to 1,000V

  • Low-voltage Switchgear GGD Series
  • Low-voltage Switchgear GCK / GCL Series
  • Low-voltage Switchgear GCK-GCL Series
  • Low-voltage Switchgear MNS Series
  • Low-voltage Switchgear GGD Series
  • Low-voltage Switchgear GCK / GCL Series
  • Low-voltage Switchgear GCK-GCL Series
  • Low-voltage Switchgear MNS Series

Product Overview

OMEK low voltage switchgears meet IEC 61439 / IEC 60439 and GB 7251.1, ideal for 50/60 Hz networks up to 1,000 V.

OMEK-GGD Series: This series is the fixed type at reasonable price with and robust construction, mainly used for standard power distribution and lighting.

OMEK-GCK / GCL Series: These are compact, flexible, easily withdrawn power and motor controlgears, ideal for quick maintenance and easy power capacity expansion.

OMEK-MNS Series: High-performance switchgears without welds and modular are suitable for high short circuit stability (up to 80 kA) and continuous operation in important workplaces.

OMEK Low Voltage Switchgear Series

What it is

The GGD low voltage switchgear is an enclosed cabinet installed to transform, distribute and control electrical energy at a low cost.

Key Features

  • 1. Robust steel framework
    2.00 mm thick C-shaped framework, 2.5 mm thick G-shaped crossbeams & 8MF cold-formed steel.
  • 2. Optimized thermal ventilation
    Louvered vents on the bottom for optimized thermal ventilation and excellent heat dissipation.
  • 3. High-strength galvanized hinges
    This design ensures easy installation and removal.
  • 4. High adaptability
    Standard modular mounting holes allow the easy installation of different components.
  • 5. Ample internal wiring space
    Enough working space for technicians, and less insulation damage caused by insufficient cable bending radius.
  • 6. Reliable safety grounding
    A complete grounding protection circuit is provided to ensure grounding continuity.

Recommended Application

Low voltage power supply and power factor correction, for example, factory lighting and power distribution.

What it is

GCK and GCL usually work together, with GCK used for controlling electrical power and GCL distributing power. They are used for power distribution, reactive power compensation, metering, lighting, and motor control in power plants and high-rise buildings.

Key Features

  • 1. Zero-Downtime Maintenance & Lower Downtime Loss
    Lower downtime maintenance cost significantly as the faulty module could be replaced in 5 minutes.
  • 2. Compact Design & Smaller Footprint
    Save 30%~50% of the floor space by compact design of 9-tier drawer and separate power cables into one cabinet, greatly reducing rental costs.
  • 3. Lower Accident Rate & Higher Personnel Safety
    Designed with mechanical interlock and automatic insulating safety barriers, there is a lower risk of electrical shock when the drawer is withdrawn (zero voltage maintenance).
  • 4. Standardized Design & Minimized Retrofitting Costs
    Standard 25mm modular holes enable easy and cost-effective expansion and upgrade. Additional drawers can be added to existing infrastructure, and additional panels can be installed without replacing infrastructure.
  • 5. High Efficiency & Smart Automation
    Local, Remote, and Auto modes are available for safe on-site maintenance and immediate-stop automatic operation just from control rooms, saving labor and cost.
  • 6. Flexible Busbar System
    This low voltage switchgear series 3P4W and 3P5W are designed for high compactibility for both old and new projects, greatly improving personnel safety.

Used For

Ideal for continuous running in waterworks, wastewater treatment plants, commercial buildings, and medical institutions.

What it is

A high-grade, weld-free modular cabinet with withdrawable drawers, used for mission-critical power distribution and intelligent MCC.

Key Features

  • 1. Weld-Free Modular Assembly
    Made of C-shaped profiles (E=25mm), locking self-tapping screws, and Grade 8.8 high-strength bolts, eliminating thermal deformation.
  • 2. High-Density Modular Drawers
    9 drawer tiers per cubicle (1/4-unit modules), with the highest space utilization and interchanging capabilities.
  • 3. Computer Communication Interface
    Smart communication interfaces for DCS, PLC, or power monitoring systems, allowing remote monitoring and data collection in heavy industries.
  • 4. MCC Capability
    Supports centralized start/stop, protection, and interlocking control for multi-circuit motors in flexible electrical connections, including high-capacity motors and complex industrial applications.
  • 5. High Breaking Capacity
    The MNS low voltage switchgear delivers high-performance circuit breakers, it can rapidly breake short-circuit fault currents, greatly protecting critical downstream equipment.
  • 6. Superior Dynamic & Thermal Stability
    With horizontal busbar short-time withstand current of 50~80kA (1s) and a peak withstand current of 105-176 kA, it can withstand large electrodynamic forces and thermal shock caused by extreme short circuit.

Ideal For

Data centers, hospitals, heavy metallurgical plants, offshore installations, utility distribution networks.

Selection Comparison Table Between GGD, GCK/GCL and MNS


 

ParametersGGDGCK/GCLMNS
Rated Insulation Voltage660V, 1000V660V, 1000V660V, 1000V
Rated Operational Voltage380V380V, 660V380V, 600V
Rated Frequency50Hz, 60Hz50Hz, 60Hz50Hz, 60Hz
Rated Current of Horizontal Busbar≤3150A≤3150A4000A
Rated Current of Vertical Busbar630A, 800A, 1200A630A, 800A, 1200A1000A
Rated Short-time Withstand Current50kA/1s50kA/1s, 80kA/1s50kA/1s ~ 80kA/1s
IP RatingIP4XIP30, IP40IP40, IP50, IP54
AdvantagesLow initial cost; robust construction; high component compatibility; easy installation & maintenance; excellent heat dissipation; high compatibility of internal componentsCompact design; high safety; low downtime loss; easy capacity expansion; smart multi-mode automationHigh cabinet precision and good rigidity; ready for automation & MCC; superior mechanical & electrical strength, higher safety; easy capacity expansion; space-saving; high IP protection rate
DisadvantagesComplete power shutdown during maintenance; longer downtime & more production loss; more footprintModerate compartment sealing; lower corrosion & deformation resistance; drawer sticking over timeHigh initial cost, high maintenance difficulty, & strict installation requirements
Environmental Conditions-5℃~+40℃; daily average temperature ≤ +35℃; altitude ≤2000m; ≤ relative humidity of 50% at 40℃-5℃~+40℃; daily average temperature ≤ +35℃; altitude ≤2000m; ≤ relative humidity of 50% at 40℃-5℃~+40℃; daily average temperature ≤ +35℃; altitude ≤2000m; ≤ relative humidity of 50% at 40℃
Uninterrupted Capacity ExpansionNoYesYes
Installation Dimensions (L*W*H, cm)110.00 * 120.00 * 220.002200.00 * 1500.00 * 1600.002200.00 * 1500.00 * 1600.00
Net Weight (kg)50024502450
StandardsGB7251.1, IEC60439GB7251.1, JB/T9661, IEC60439-1GB7251.1, JB/T9661, IEC60439

Low Voltage Switchgear Installation Requirements

DimensionA (mm)B (mm)
Receiving or feeding power600486
Receiving power or bus connection800686
Receiving power or bus connection1000886

Why OMEK Low Voltage Switchgear Stands Out

20+ Years of Expertise: OMEK has 20+ years of manufacturing expertise, helping 350+ successful projects across 50+ countries.

Seamless Transformer-to-Switchgear Integration: As a leading transformer manufacturer, OMEK produces our GGD, GCK/GCL, and MNS switchgears to match different project requirements, giving you a turnkey power distribution solution.

Strict IEC & National Standard Compliance: Each unit meets IEC 61439 (IEC 60439) and GB 7251.1 standards and undergoes 100% factory routine testing before shipment.

Flexible Custom Engineering (OEM/ODM): Different busbar ratings (up to 4000A), IP protection levels (IP30 to IP54), breaker brands, etc. customized to your speficied requirements.

FAQ

What is a low voltage switchgear?

Low-voltage switchgear is used to distribute and control electrical power while ensures system safety at rated voltages up to 1kV. It can be both fixed type such as GGD featuring robust structure and low price, and withdrawable type, for example, GCK/GCL & MNS desgined for easy capacity expansion, safe maintanence and automatic operation.

What is the difference between a low-voltage switchboard and switchgear?
FeatureLow-Voltage Switchgear (e.g., MNS, GCK/GCL)Low-Voltage Switchboard (e.g., GGD)
Mounting StyleWithdrawableFixed type
StandardsIEC: IEC 61439-1/-2, GB 7251.1, JB/T 9661
North America: UL 1558 / ANSI C37.20.1
IEC: IEC 61439-1/-2 (formerly IEC 60439), GB 7251.1
North America: UL 891 / NEMA PB-2
MaintenanceHot-swappable (zero/minimal downtime)Requires full or partial shutdown
Internal IsolationHigh (isolated busbar & drawer compartments)Basic (shared enclosure space)
Fault ToleranceHigher short-time withstand ratingsStandard commercial fault ratings
Footprint & CostCompact footprint; higher upfront investmentLarger footprint; lower upfront cost
Why do some low-voltage panels lack a separate busbar compartment?

Internal segregation is inadequate, either Form 1 or 2a. Form 4 level is normally used with large capacity incoming lines of 3200A or 4000A. For instance, Form 4 Type 6 has totally independent busbar chambers typically located in the top or bottom of the cabinet and of course is more expensive.

What are the installation requirements for a low voltage switchgear?

Environment & Altitude: Keep dry and well ventilated; -5°C to +40°C; altitude ≤ 2000 m.

Foundation Flatness: For MNS and GCK/GCL switchgears, the flatness of the foundation is also important, and needs to be placed on metal foundation channel steel so that flatness of the cabinets is not compromised and smooth operation of the drawers is maintained.

Maintenance Access: The clearance in front of the cabinet is 1.5~2.0 m, and the clearance in the back is + 0.8~1.0 m, which all depend on the wiring method. The distance from GGD to the wall can be shortened.

Grounding & Fastening: Grounding bar must be firmly attached to the ground. Split-shipped horizontal busbars must be torqued to their specified torque requirements when they are put together on site.

How to choose between MNS, GCK/GCL, and GGD switchgear?

Choose MNS: For heavy duty, continual welding applications (power plants, petrochemical, data center), MNS Series is the preferred choice for power plants, petrochemicals, and data centers which demand weld-free modular frames, high-density drawers (up to 9 tiers / 1/4-unit modules), and high short-circuit withstand strength (50–80 kA).

Choose GCK/GCL: Use GCK / GCL Series for cost-effective withdrawable solutions in commercial buildings, waterworks and hospitals where quick module replacement is required.

Choose GGD: Opt for GGD Series for budget-friendly applications in fixed power distribution systems with simple maintenance demands (rated up to 3150A / 50 kA).

Contact with Us!

Solve the problem and obtain the quotation.
Wide Contact Form 2