{"id":26213,"date":"2026-10-12T08:45:49","date_gmt":"2026-10-12T08:45:49","guid":{"rendered":"https:\/\/omekpower.com\/?p=24115"},"modified":"2026-10-26T08:53:28","modified_gmt":"2026-10-26T08:53:28","slug":"transformer-routine-tests","status":"publish","type":"post","link":"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/","title":{"rendered":"Tests de routine des transformateurs : types, proc\u00e9dures et normes IEC"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_91 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title ez-toc-toggle\" style=\"cursor:pointer\">Content<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i\" >Que sont les essais de routine ?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-2\" >Pourquoi les essais de routine sont-ils importants ?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-3\" >Essais de routine vs essais de type vs essais sp\u00e9ciaux<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-4\" >Essais de routine des transformateurs selon les normes IEC<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-5\" >Diff\u00e9rences entre les essais de routine des transformateurs immerg\u00e9s dans l&rsquo;huile et des transformateurs secs<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-6\" >Essais communs aux deux types :<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-7\" >Essais sp\u00e9cifiques aux transformateurs immerg\u00e9s dans l&rsquo;huile :<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-8\" >Essais sp\u00e9cifiques aux transformateurs secs :<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-9\" >Types d&rsquo;essais de routine des transformateurs<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-10\" >Mesure de la r\u00e9sistance des enroulements<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-11\" >Essai du rapport de tension et du d\u00e9phasage<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-12\" >Mesure de l&rsquo;imp\u00e9dance de court-circuit et des pertes en charge<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-13\" >Mesure des pertes \u00e0 vide et du courant \u00e0 vide<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-14\" >Essai de tension appliqu\u00e9e<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-15\" >Essai de tenue \u00e0 la tension induite<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-16\" >Mesure des d\u00e9charges partielles (transformateurs secs IEC 60076-11)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-17\" >Essai de fuite ou d&rsquo;\u00e9tanch\u00e9it\u00e9 de la cuve (transformateurs immerg\u00e9s dans l&rsquo;huile)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-18\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-18\" >Essais du liquide isolant (transformateurs immerg\u00e9s dans l&rsquo;huile)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-19\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-19\" >Essai de fonctionnement du changeur de prises en charge (si \u00e9quip\u00e9 d&rsquo;un OLTC)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-20\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-20\" >V\u00e9rification du rapport et de la polarit\u00e9 des transformateurs de courant int\u00e9gr\u00e9s (le cas \u00e9ch\u00e9ant)<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-21\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-21\" >Comment lire un rapport d&rsquo;essai de routine de transformateur ?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-22\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-22\" >Conclusion<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-23\" href=\"https:\/\/omekpower.com\/fr\/tests-de-routine-du-transformateur\/#i-23\" >Questions fr\u00e9quentes<\/a><\/li><\/ul><\/nav><\/div>\n<p>Les essais de routine avant livraison des <a href=\"https:\/\/omekpower.com\/\" target=\"_blank\" rel=\"noopener\">transformateurs<\/a> sont r\u00e9alis\u00e9s afin de v\u00e9rifier les performances \u00e9lectriques, de contr\u00f4ler l&rsquo;int\u00e9grit\u00e9 de l&rsquo;isolation et de rechercher d&rsquo;\u00e9ventuels d\u00e9fauts de fabrication.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/oil-type-transformer-10.10.webp\" alt=\"Transformateur de distribution sur un poteau \u00e9lectrique soumis aux essais de routine avant livraison selon les normes IEC\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24136 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/oil-type-transformer-10.10.webp\" alt=\"Transformateur de distribution sur un poteau \u00e9lectrique soumis aux essais de routine avant livraison selon les normes IEC\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24136 size-full\"><\/noscript><\/p>\n<p>Ces essais sont effectu\u00e9s pour garantir que chaque transformateur est conforme aux exigences techniques sp\u00e9cifi\u00e9es, conform\u00e9ment aux normes IEC 60076 applicables. Ce guide couvre les types d&rsquo;essais de routine, les proc\u00e9dures, les objectifs, les crit\u00e8res d&rsquo;acceptation et les risques potentiels en cas d&rsquo;\u00e9chec des essais.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"i\"><\/span>Que sont les essais de routine ?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Les essais de routine des transformateurs sont effectu\u00e9s sur chaque unit\u00e9 avant <a href=\"https:\/\/omekpower.com\/fr\/paiement-et-livraison\/\" target=\"_blank\" rel=\"noopener\">livraison<\/a> afin de s&rsquo;assurer qu&rsquo;elle satisfait aux normes pertinentes et aux exigences techniques sp\u00e9cifiques.<\/p>\n<p>Selon le type et la conception du transformateur, les essais sont r\u00e9alis\u00e9s conform\u00e9ment aux <a href=\"https:\/\/omekpower.com\/fr\/certification\/\" target=\"_blank\" rel=\"noopener\">normes IEC 60076<\/a> : IEC 60076-1, IEC 60076-3 et IEC 60076-11. Des proc\u00e9dures et des crit\u00e8res d&rsquo;acceptation sont d\u00e9finis pour chaque essai.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"i-2\"><\/span>Pourquoi les essais de routine sont-ils importants ?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>\u2705\ufe0f V\u00e9rifier les performances \u00e9lectriques : d\u00e9terminer l&rsquo;\u00e9cart entre les valeurs sp\u00e9cifi\u00e9es et les valeurs observ\u00e9es des param\u00e8tres importants susceptibles d&rsquo;affecter les performances du transformateur, notamment le rapport de tension, les pertes de puissance, etc.<\/p>\n<p>\u2705\ufe0f D\u00e9tecter les d\u00e9fauts de fabrication : identifier les probl\u00e8mes potentiels au niveau des enroulements, des connexions \u00e9lectriques et de l&rsquo;isolation avant la livraison.<\/p>\n<p>\u2705\ufe0f R\u00e9duire les risques op\u00e9rationnels : minimiser le risque de d\u00e9faillances, d&rsquo;arr\u00eats impr\u00e9vus et de r\u00e9parations co\u00fbteuses apr\u00e8s l&rsquo;installation.<\/p>\n<p>\u2705\ufe0f Faciliter l&rsquo;acceptation client et la tra\u00e7abilit\u00e9 : fournir des enregistrements d&rsquo;essais permettant aux clients de confirmer la qualit\u00e9 du produit et les r\u00e9sultats des essais lors des <a href=\"https:\/\/omekpower.com\/fr\/controle-qualite\/\" target=\"_blank\" rel=\"noopener\">contr\u00f4les qualit\u00e9<\/a> ou du d\u00e9pannage.<\/p>\n<p>Les essais de routine minimisent le risque de livrer des transformateurs non conformes. La r\u00e9ussite des essais de routine ne garantit toutefois pas qu&rsquo;un transformateur ne tombera jamais en panne pendant son fonctionnement ; d&rsquo;autres facteurs, tels qu&rsquo;une installation et une maintenance correctes ainsi que les conditions d&rsquo;exploitation, sont \u00e9galement importants.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"i-3\"><\/span><a href=\"https:\/\/omekpower.com\/fr\/test\/\" target=\"_blank\" rel=\"noopener\">Essais de routine vs essais de type vs essais sp\u00e9ciaux<\/a><span class=\"ez-toc-section-end\"><\/span><\/h2>\n<table style=\"border-collapse: collapse; width: 100%; height: 147px;\">\n<tbody>\n<tr style=\"height: 27px;\">\n<td style=\"width: 25%; text-align: center; height: 27px;\" colspan=\"4\"><span style=\"font-size: 14pt;\"><strong>Essais de routine vs essais de type vs essais sp\u00e9ciaux<\/strong><\/span><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 25%; height: 24px; text-align: center;\"><\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\"><strong>Essais de routine<\/strong><\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\"><strong>Essais de type<\/strong><\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\"><strong>Essais sp\u00e9ciaux<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 25%; height: 24px; text-align: center;\"><strong>Objectif principal<\/strong><\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">D\u00e9tecter les d\u00e9fauts de fabrication et v\u00e9rifier les param\u00e8tres \u00e9lectriques cl\u00e9s de chaque transformateur<\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">V\u00e9rifier les performances de conception, telles que l&rsquo;\u00e9l\u00e9vation de temp\u00e9rature, la tenue di\u00e9lectrique et la tenue aux courts-circuits<\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">\u00c9valuer des caract\u00e9ristiques suppl\u00e9mentaires ou des exigences de performance sp\u00e9cifiques non couvertes par les essais de routine<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 25%; height: 24px; text-align: center;\"><strong>Quand sont-ils r\u00e9alis\u00e9s<\/strong><\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">Avant livraison, sur chaque unit\u00e9<\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">Lors de l&rsquo;introduction d&rsquo;une nouvelle conception ; essais par \u00e9chantillonnage tous les cinq ans<\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">Selon les exigences sp\u00e9cifiques du client<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 25%; height: 24px; text-align: center;\"><strong>Exemples typiques<\/strong><\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">R\u00e9sistance des enroulements, rapport de tension, pertes en charge et essais di\u00e9lectriques<\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">Essai d&rsquo;\u00e9l\u00e9vation de temp\u00e9rature, essai au choc de foudre et mesure du niveau sonore, selon la norme applicable<\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">Mesure de capacit\u00e9, essais di\u00e9lectriques sp\u00e9ciaux et autres essais convenus, selon la norme applicable<\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 25%; height: 24px; text-align: center;\"><strong>Requis pour chaque unit\u00e9 ?<\/strong><\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">Oui<\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">Non<\/td>\n<td style=\"width: 25%; height: 24px; text-align: center;\">Non<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><span class=\"ez-toc-section\" id=\"i-4\"><\/span>Essais de routine des transformateurs selon les normes IEC<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Les essais de routine des transformateurs sont r\u00e9alis\u00e9s conform\u00e9ment aux normes IEC 60076. Les exigences sp\u00e9cifiques varient selon le type, la conception et les caract\u00e9ristiques nominales du transformateur.<\/p>\n<ul>\n<li>IEC 60076-1 C Exigences g\u00e9n\u00e9rales : fournit les exigences g\u00e9n\u00e9rales relatives aux transformateurs de puissance et \u00e0 certains essais de routine, tels que la r\u00e9sistance des enroulements, le rapport de tension, les pertes en charge et les mesures de pertes \u00e0 vide.<\/li>\n<li>IEC 60076-3 C Niveaux d&rsquo;isolation et essais di\u00e9lectriques : couvre les niveaux d&rsquo;isolation et divers essais di\u00e9lectriques, tels que les essais de tension appliqu\u00e9e ou de tension induite.<\/li>\n<li>IEC 60076-11 C Transformateurs secs : sp\u00e9cifie les exigences relatives aux <a href=\"https:\/\/omekpower.com\/fr\/fabricant-de-transformateurs-secs\/\" target=\"_blank\" rel=\"noopener\">transformateurs secs<\/a>, y compris leurs essais de routine applicables, tels que la mesure des d\u00e9charges partielles.<\/li>\n<\/ul>\n<h2><span class=\"ez-toc-section\" id=\"i-5\"><\/span>Diff\u00e9rences entre les essais de routine des transformateurs immerg\u00e9s dans l&rsquo;huile et des transformateurs secs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"i-6\"><\/span>Essais communs aux deux types :<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Mesure de la r\u00e9sistance des enroulements<\/p>\n<p>Essai du rapport de tension et du d\u00e9phasage<\/p>\n<p>Mesure de l&rsquo;imp\u00e9dance de court-circuit et des pertes en charge<\/p>\n<p>Mesure des pertes \u00e0 vide et du courant \u00e0 vide<\/p>\n<p>Essai de tension appliqu\u00e9e<\/p>\n<p>Essai de tenue \u00e0 la tension induite<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-7\"><\/span>Essais sp\u00e9cifiques aux <a href=\"https:\/\/omekpower.com\/fr\/fabricant-de-transformateurs-immerges-dans-lhuile\/\" target=\"_blank\" rel=\"noopener\">transformateurs immerg\u00e9s dans l&rsquo;huile<\/a> :<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>\u2705\ufe0f <strong>Essais d&rsquo;\u00e9tanch\u00e9it\u00e9 ou de fuite de la cuve<\/strong> : d\u00e9terminer si la cuve et le syst\u00e8me d&rsquo;\u00e9tanch\u00e9it\u00e9 emp\u00eachent le liquide isolant de fuir.<\/p>\n<p>\u2705\ufe0f <strong>Essais du liquide isolant<\/strong> : tester les propri\u00e9t\u00e9s appropri\u00e9es du liquide isolant, selon les exigences.<\/p>\n<p>\u2705\ufe0f <strong>Contr\u00f4les de l&rsquo;isolation du noyau et du ch\u00e2ssis<\/strong> : pour les conceptions \u00e0 noyau ou ch\u00e2ssis isol\u00e9s, selon les besoins.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-8\"><\/span>Essais sp\u00e9cifiques aux transformateurs secs :<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>\u2705\ufe0f <strong>Mesure des d\u00e9charges partielles<\/strong> : essai de routine sp\u00e9cifi\u00e9 par l&rsquo;IEC 60076-11.<\/p>\n<p>\u2705\ufe0f <strong>Contr\u00f4les du syst\u00e8me d&rsquo;isolation<\/strong> : garantir les performances du syst\u00e8me d&rsquo;isolation solide en r\u00e9alisant les essais di\u00e9lectriques appropri\u00e9s.<\/p>\n<p>D&rsquo;autres essais, tels que le fonctionnement du changeur de prises en charge et la v\u00e9rification du rapport et de la polarit\u00e9 des transformateurs de courant int\u00e9gr\u00e9s, sont r\u00e9alis\u00e9s s&rsquo;ils s&rsquo;appliquent \u00e0 la conception de transformateur requise.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"i-9\"><\/span>Types d&rsquo;essais de routine des transformateurs<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"i-10\"><\/span>Mesure de la r\u00e9sistance des enroulements<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cet essai v\u00e9rifie l&rsquo;\u00e9tat des jonctions d&rsquo;enroulement, des connexions de sortie et des contacts du changeur de prises, et r\u00e9v\u00e8le une r\u00e9sistance anormale pouvant indiquer de mauvaises connexions ou un d\u00e9faut dans l&rsquo;enroulement.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Winding-Resistance-Measurement-10.10.webp\" alt=\"Deux techniciens mesurant la r\u00e9sistance des enroulements d&#039;un transformateur \u00e0 l&#039;aide d&#039;un ohmm\u00e8tre d&#039;enroulement lors des essais de routine\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24139 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Winding-Resistance-Measurement-10.10.webp\" alt=\"Deux techniciens mesurant la r\u00e9sistance des enroulements d&#039;un transformateur \u00e0 l&#039;aide d&#039;un ohmm\u00e8tre d&#039;enroulement lors des essais de routine\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24139 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Ohmm\u00e8tre de r\u00e9sistance d&rsquo;enroulement de transformateur<\/p>\n<p><strong>C\u00f4t\u00e9 HT<\/strong> : v\u00e9rifier le d\u00e9s\u00e9quilibre de r\u00e9sistance de ligne et mesurer la r\u00e9sistance de l&rsquo;enroulement \u00e0 chaque position de prise.<\/p>\n<p><strong>C\u00f4t\u00e9 BT<\/strong> : le c\u00f4t\u00e9 BT poss\u00e8de la borne neutre, il convient donc de v\u00e9rifier \u00e0 la fois le d\u00e9s\u00e9quilibre de r\u00e9sistance de ligne et le d\u00e9s\u00e9quilibre de r\u00e9sistance de phase.<\/p>\n<p><strong>Normes OMEK<\/strong> : sur les c\u00f4t\u00e9s HT et BT, le d\u00e9s\u00e9quilibre de r\u00e9sistance de ligne est de 2 %, tandis que le d\u00e9s\u00e9quilibre de r\u00e9sistance de phase est de 4 %. Le d\u00e9s\u00e9quilibre de r\u00e9sistance de ligne mesur\u00e9 par <a href=\"https:\/\/omekpower.com\/\" target=\"_blank\" rel=\"noopener\">OMEK<\/a> est g\u00e9n\u00e9ralement d&rsquo;environ 0,0* %, bien en dessous des normes.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : l&rsquo;\u00e9chec de cet essai peut provoquer une surchauffe localis\u00e9e, davantage de pertes de puissance, une d\u00e9t\u00e9rioration suppl\u00e9mentaire des connexions \u00e9lectriques et une d\u00e9faillance du transformateur en cours de fonctionnement.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-11\"><\/span>Essai du rapport de tension et du d\u00e9phasage<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cet essai v\u00e9rifie le rapport de spires des enroulements, confirme le groupe vectoriel et le d\u00e9phasage corrects, et contr\u00f4le les erreurs de rapport de tension aux diff\u00e9rentes positions de prise.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Voltage-Ratio-and-Phase-Displacement-Test-10.10.webp\" alt=\"C\u00e2bles d&#039;essai rep\u00e9r\u00e9s par couleur fix\u00e9s aux travers\u00e9es du transformateur pour l&#039;essai du rapport de tension et du d\u00e9phasage\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24140 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Voltage-Ratio-and-Phase-Displacement-Test-10.10.webp\" alt=\"C\u00e2bles d&#039;essai rep\u00e9r\u00e9s par couleur fix\u00e9s aux travers\u00e9es du transformateur pour l&#039;essai du rapport de tension et du d\u00e9phasage\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24140 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Appareil de mesure du rapport de transformation<\/p>\n<p><strong>Proc\u00e9dure de base<\/strong> : connecter un appareil de mesure du rapport de transformation aux enroulements haute tension et basse tension. Mesurer le rapport de tension \u00e0 chaque position de prise et v\u00e9rifier le groupe vectoriel et le d\u00e9phasage.<\/p>\n<p><strong>Normes OMEK<\/strong> : OMEK mesure l&rsquo;erreur de rapport de tension \u00e0 chaque point des prises. L&rsquo;erreur doit \u00eatre inf\u00e9rieure \u00e0 0,4 % \u00e0 la position de prise principale et ne pas d\u00e9passer 0,5 % \u00e0 toute autre position de prise. Le crit\u00e8re d&rsquo;acceptation pour l&rsquo;inspection interne est de 0,4 %.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : l&rsquo;\u00e9chec de l&rsquo;essai peut entra\u00eener une tension de sortie trop \u00e9lev\u00e9e ou trop faible et une r\u00e9gulation de tension instable. Des courants de circulation \u00e9lev\u00e9s pourraient se produire si les transformateurs sont exploit\u00e9s en parall\u00e8le avec une connexion incorrecte des groupes vectoriels, ce qui pourrait endommager l&rsquo;\u00e9quipement.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-12\"><\/span>Mesure de l&rsquo;imp\u00e9dance de court-circuit et des pertes en charge<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cet essai est r\u00e9alis\u00e9 pour mesurer l&rsquo;imp\u00e9dance de court-circuit et les <a href=\"https:\/\/omekpower.com\/fr\/types-de-pertes-de-transformateur\/\" target=\"_blank\" rel=\"noopener\">pertes<\/a> en charge des enroulements.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Short-Circuit-Impedance-and-Load-Loss-Measurement-10.10.webp\" alt=\"Technicien utilisant un syst\u00e8me de mesure des pertes de transformateur pour l&#039;essai d&#039;imp\u00e9dance de court-circuit et de pertes en charge\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24141 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Short-Circuit-Impedance-and-Load-Loss-Measurement-10.10.webp\" alt=\"Technicien utilisant un syst\u00e8me de mesure des pertes de transformateur pour l&#039;essai d&#039;imp\u00e9dance de court-circuit et de pertes en charge\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24141 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Syst\u00e8me de mesure des pertes de transformateur, alimentation d&rsquo;essai et montage d&rsquo;essai de court-circuit<\/p>\n<p><strong>Proc\u00e9dure de base<\/strong> : court-circuiter un enroulement et appliquer une tension r\u00e9duite sur l&rsquo;autre enroulement jusqu&rsquo;\u00e0 atteindre le courant d&rsquo;essai sp\u00e9cifi\u00e9, en mesurant les pertes en charge et les imp\u00e9dances de court-circuit. Comparer les r\u00e9sultats aux exigences techniques du client.<\/p>\n<p><strong>Normes OMEK<\/strong> : les r\u00e9sultats d&rsquo;essai sont \u00e9valu\u00e9s sur la base des accords techniques des clients ou des sp\u00e9cifications du projet.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : toute perte en charge importante peut entra\u00eener une surchauffe du transformateur et r\u00e9duire l&rsquo;efficacit\u00e9 \u00e9nerg\u00e9tique. Une chute de tension excessive en charge ou une modification des courants de court-circuit peut \u00eatre caus\u00e9e par une imp\u00e9dance de court-circuit anormale.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-13\"><\/span>Mesure des pertes \u00e0 vide et du courant \u00e0 vide<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Pour mesurer les pertes dans le noyau et le courant \u00e0 vide \u00e0 la tension et \u00e0 la fr\u00e9quence nominales.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/No-Load-Loss-and-No-Load-Current-Measurement-10.10.webp\" alt=\"Travers\u00e9es haute tension du transformateur et pinces d&#039;essai pr\u00e9par\u00e9es pour la mesure des pertes \u00e0 vide et du courant \u00e0 vide\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24143 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/No-Load-Loss-and-No-Load-Current-Measurement-10.10.webp\" alt=\"Travers\u00e9es haute tension du transformateur et pinces d&#039;essai pr\u00e9par\u00e9es pour la mesure des pertes \u00e0 vide et du courant \u00e0 vide\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24143 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Syst\u00e8me de mesure des pertes de transformateur, analyseur de puissance de pr\u00e9cision<\/p>\n<p><strong>Proc\u00e9dure de base<\/strong> : appliquer la tension nominale \u00e0 la fr\u00e9quence nominale \u00e0 un enroulement, l&rsquo;autre enroulement \u00e9tant ouvert. Mesurer et enregistrer les pertes \u00e0 vide et le courant \u00e0 vide.<\/p>\n<p><strong>Normes OMEK<\/strong> : les pertes \u00e0 vide doivent satisfaire aux accords techniques des clients ou aux sp\u00e9cifications du projet. Le courant \u00e0 vide doit \u00e9galement \u00eatre mesur\u00e9 et enregistr\u00e9 pour v\u00e9rification.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : des pertes \u00e0 vide excessives augmenteront la consommation d&rsquo;\u00e9nergie pendant toute la dur\u00e9e de vie du transformateur. Un courant \u00e0 vide \u00e9lev\u00e9 peut signaler certains d\u00e9fauts dans le noyau ou l&rsquo;isolation, susceptibles d&rsquo;affecter les performances et la fiabilit\u00e9 du transformateur.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-14\"><\/span>Essai de tension appliqu\u00e9e<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Pour confirmer la capacit\u00e9 d&rsquo;isolation entre l&rsquo;enroulement haute tension, l&rsquo;enroulement basse tension et la terre sous la tension d&rsquo;essai \u00e0 fr\u00e9quence industrielle.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Applied-Voltage-Test-10.10-2.webp\" alt=\"Montage de l&#039;essai de tension appliqu\u00e9e d&#039;un transformateur dans une zone d&#039;essai d&#039;usine \u00e0 l&#039;aide d&#039;un cylindre d&#039;essai haute tension et d&#039;une unit\u00e9 de commande\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24158 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Applied-Voltage-Test-10.10-2.webp\" alt=\"Montage de l&#039;essai de tension appliqu\u00e9e d&#039;un transformateur dans une zone d&#039;essai d&#039;usine \u00e0 l&#039;aide d&#039;un cylindre d&#039;essai haute tension et d&#039;une unit\u00e9 de commande\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24158 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Testeur de tension de tenue en CA<\/p>\n<p><strong>Proc\u00e9dure de base<\/strong> : connecter la tension \u00e0 tester \u00e0 l&rsquo;enroulement haute tension, en reliant l&rsquo;enroulement basse tension \u00e0 la terre. Retester ensuite l&rsquo;enroulement basse tension selon la m\u00eame proc\u00e9dure d&rsquo;essai. Maintenir la tension d&rsquo;essai pendant 60 secondes et observer s&rsquo;il y a effondrement de tension, claquage d&rsquo;isolation ou amor\u00e7age.<\/p>\n<p><strong>Normes OMEK<\/strong> : la tension d&rsquo;essai est maintenue pendant 60 secondes. S&rsquo;il n&rsquo;y a ni claquage d&rsquo;isolation ni amor\u00e7age et que la tension d&rsquo;essai reste stable pendant l&rsquo;essai, le transformateur r\u00e9ussit l&rsquo;essai.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : en cours de fonctionnement, une d\u00e9faillance de l&rsquo;isolation peut provoquer un courant de fuite, un court-circuit ou un claquage \u00e9lectrique, susceptibles d&rsquo;endommager le transformateur ou de causer des arr\u00eats impr\u00e9vus.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-15\"><\/span>Essai de tenue \u00e0 la tension induite<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Cet essai v\u00e9rifie l&rsquo;isolation entre les spires et les couches des enroulements du transformateur.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Induced-Voltage-Withstand-Test-10.10.webp\" alt=\"Montage de l&#039;essai de tenue \u00e0 la tension induite avec alimentation \u00e0 fr\u00e9quence variable et groupe moteur-g\u00e9n\u00e9rateur pour les essais d&#039;isolation du transformateur\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24145 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Induced-Voltage-Withstand-Test-10.10.webp\" alt=\"Montage de l&#039;essai de tenue \u00e0 la tension induite avec alimentation \u00e0 fr\u00e9quence variable et groupe moteur-g\u00e9n\u00e9rateur pour les essais d&#039;isolation du transformateur\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24145 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Syst\u00e8me d&rsquo;essai de tension induite, alimentation \u00e0 fr\u00e9quence variable<\/p>\n<p><strong>Proc\u00e9dure de base<\/strong> : comme le c\u00f4t\u00e9 haute tension n\u00e9cessite une tension d&rsquo;essai plus \u00e9lev\u00e9e, l&rsquo;essai est g\u00e9n\u00e9ralement r\u00e9alis\u00e9 en appliquant la tension \u00e0 l&rsquo;enroulement basse tension pour des raisons de commodit\u00e9. La dur\u00e9e de l&rsquo;essai est de 40 secondes avec une tension appliqu\u00e9e de 800 V.<\/p>\n<p><strong>Normes OMEK<\/strong> : la tension d&rsquo;essai est appliqu\u00e9e pendant 40 secondes \u00e0 800 V dans les conditions d&rsquo;essai. Le transformateur doit r\u00e9ussir l&rsquo;essai si aucune diminution soudaine de tension ni aucun autre signe de d\u00e9faillance de l&rsquo;isolation n&rsquo;est constat\u00e9 pendant l&rsquo;essai.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : en fonctionnement, des courts-circuits, une surchauffe et des dommages \u00e0 l&rsquo;enroulement peuvent survenir en raison d&rsquo;une isolation d&rsquo;enroulement d\u00e9faillante.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-16\"><\/span>Mesure des d\u00e9charges partielles (transformateurs secs IEC 60076-11)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Pour surveiller les d\u00e9charges partielles dans le syst\u00e8me d&rsquo;isolation du transformateur et d\u00e9terminer la qualit\u00e9 de l&rsquo;isolation.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Partial-Discharge-Measurement-10.10.webp\" alt=\"Transformateur sec soumis \u00e0 une mesure des d\u00e9charges partielles dans une salle d&#039;essai blind\u00e9e selon l&#039;IEC 60076-11\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24147 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Partial-Discharge-Measurement-10.10.webp\" alt=\"Transformateur sec soumis \u00e0 une mesure des d\u00e9charges partielles dans une salle d&#039;essai blind\u00e9e selon l&#039;IEC 60076-11\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24147 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Syst\u00e8me de mesure des d\u00e9charges partielles<\/p>\n<p><strong>Proc\u00e9dure de base<\/strong> : appliquer la tension d&rsquo;essai conform\u00e9ment \u00e0 la norme et enregistrer l&rsquo;activit\u00e9 de d\u00e9charges partielles \u00e0 l&rsquo;aide d&rsquo;un syst\u00e8me de mesure des d\u00e9charges partielles. Noter la charge apparente en picocoulombs (pC) et la comparer \u00e0 la limite d&rsquo;acceptation.<\/p>\n<p><strong>Normes OMEK<\/strong> : les r\u00e9sultats d&rsquo;essai sont bas\u00e9s sur les accords techniques des clients ou les sp\u00e9cifications du projet.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : des d\u00e9charges partielles excessives peuvent entra\u00eener des vides, des fissures ou d&rsquo;autres d\u00e9fauts dans l&rsquo;isolation. Avec le temps, ces d\u00e9fauts peuvent compromettre de plus en plus l&rsquo;isolation et provoquer une d\u00e9faillance \u00e9lectrique.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-17\"><\/span>Essai de fuite ou d&rsquo;\u00e9tanch\u00e9it\u00e9 de la cuve (transformateurs immerg\u00e9s dans l&rsquo;huile)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Pour pr\u00e9venir les fuites d&rsquo;huile isolante en cours de fonctionnement, v\u00e9rifier l&rsquo;int\u00e9grit\u00e9 d&rsquo;\u00e9tanch\u00e9it\u00e9 de la cuve et identifier les fuites d&rsquo;huile autour des soudures, des joints et des raccordements.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Tank-Leak-or-Tightness-Test-10.10.webp\" alt=\"Cuve de transformateur immerg\u00e9 dans l&#039;huile soumise \u00e0 un essai de fuite et d&#039;\u00e9tanch\u00e9it\u00e9 \u00e0 l&#039;aide d&#039;un \u00e9quipement d&#039;essai de pression \u00e0 serrage pneumatique\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24149 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Tank-Leak-or-Tightness-Test-10.10.webp\" alt=\"Cuve de transformateur immerg\u00e9 dans l&#039;huile soumise \u00e0 un essai de fuite et d&#039;\u00e9tanch\u00e9it\u00e9 \u00e0 l&#039;aide d&#039;un \u00e9quipement d&#039;essai de pression \u00e0 serrage pneumatique\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24149 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Manom\u00e8tre et \u00e9quipement d&rsquo;essai de pression<\/p>\n<p><strong>Proc\u00e9dure de base<\/strong> : appliquer une pression \u00e0 la cuve scell\u00e9e du transformateur, v\u00e9rifier l&rsquo;absence de fuite pendant toute la dur\u00e9e de l&rsquo;essai sur la cuve, les soudures et les raccordements.<\/p>\n<p><strong>Normes OMEK<\/strong> : appliquer une pression d&rsquo;essai de 20 kPa pendant 12 heures. L&rsquo;essai est r\u00e9ussi si aucune fuite n&rsquo;est constat\u00e9e pendant la p\u00e9riode d&rsquo;essai.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : une fuite de cuve peut entra\u00eener une perte d&rsquo;huile isolante, affaiblir les performances d&rsquo;isolation et de refroidissement, et permettre \u00e0 l&rsquo;humidit\u00e9 de p\u00e9n\u00e9trer dans le transformateur, augmentant le risque de d\u00e9t\u00e9rioration de l&rsquo;isolation et de d\u00e9faillance de l&rsquo;\u00e9quipement.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-18\"><\/span>Essais du liquide isolant (transformateurs immerg\u00e9s dans l&rsquo;huile)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Ces essais \u00e9valuent la puret\u00e9 et les performances d&rsquo;isolation de l&rsquo;huile, et d\u00e9tectent les contaminants et l&rsquo;humidit\u00e9 excessifs dans l&rsquo;huile isolante.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Insulating-Liquid-Tests-10.10.webp\" alt=\"Testeur de tension de claquage de l&#039;huile isolante en laboratoire avec cellules d&#039;essai pour l&#039;analyse de l&#039;isolation liquide des transformateurs\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24151 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Insulating-Liquid-Tests-10.10.webp\" alt=\"Testeur de tension de claquage de l&#039;huile isolante en laboratoire avec cellules d&#039;essai pour l&#039;analyse de l&#039;isolation liquide des transformateurs\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24151 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Testeur de tension de claquage de l&rsquo;huile isolante, testeur du facteur de dissipation di\u00e9lectrique de l&rsquo;huile, analyseur de teneur en humidit\u00e9 de l&rsquo;huile<\/p>\n<p><strong>Proc\u00e9dure de base<\/strong> : pr\u00e9lever un \u00e9chantillon d&rsquo;huile \u00e0 l&rsquo;aide d&rsquo;un r\u00e9cipient d&rsquo;\u00e9chantillonnage propre. Tester sa tension de claquage, son facteur de dissipation di\u00e9lectrique et sa teneur en humidit\u00e9 \u00e0 l&rsquo;aide des instruments appropri\u00e9s.<\/p>\n<p><strong>Normes OMEK<\/strong> : l&rsquo;essai dure 30 minutes. Alors que la norme nationale sp\u00e9cifie 40 kV et que la norme obligatoire exige 45 kV, OMEK adopte une tension de claquage minimale de 45 kV pour tous les essais.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : une faible tension de claquage peut indiquer la pr\u00e9sence d&rsquo;humidit\u00e9 ou de contaminants dans l&rsquo;huile, r\u00e9duisant sa rigidit\u00e9 di\u00e9lectrique. Une humidit\u00e9 ou une perte di\u00e9lectrique excessives peuvent acc\u00e9l\u00e9rer la d\u00e9t\u00e9rioration de l&rsquo;isolation et augmenter le risque de d\u00e9faillance \u00e9lectrique.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-19\"><\/span>Essai de fonctionnement du changeur de prises en charge (si \u00e9quip\u00e9 d&rsquo;un OLTC)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Pour v\u00e9rifier que l&rsquo;OLTC fonctionne correctement et avec pr\u00e9cision \u00e0 toutes les positions de prise, afin que la tension puisse \u00eatre ajust\u00e9e sans aucune interruption de l&rsquo;alimentation.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/On-Load-Tap-Changer-Operation-Test-10.10.webp\" alt=\"M\u00e9canisme de changeur de prises en charge (OLTC) install\u00e9 sur un transformateur pour l&#039;essai de fonctionnement et de position de prise\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24152 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/On-Load-Tap-Changer-Operation-Test-10.10.webp\" alt=\"M\u00e9canisme de changeur de prises en charge (OLTC) install\u00e9 sur un transformateur pour l&#039;essai de fonctionnement et de position de prise\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24152 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Unit\u00e9 de commande et indicateur de position de l&rsquo;OLTC, m\u00e9canisme d&rsquo;entra\u00eenement moteur de l&rsquo;OLTC<\/p>\n<p><strong>Proc\u00e9dure de base<\/strong> : actionner l&rsquo;OLTC sur toutes ses positions de prise. V\u00e9rifier que chaque position change correctement, que l&rsquo;indicateur de position correspond \u00e0 la position de prise r\u00e9elle et que le m\u00e9canisme de fonctionnement fonctionne.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : une d\u00e9faillance de l&rsquo;OLTC peut entra\u00eener un contact \u00e9lectrique d\u00e9fectueux ou une usure du contact, ou un positionnement de prise incorrect, tous ces facteurs pouvant causer des d\u00e9faillances du transformateur.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"i-20\"><\/span>V\u00e9rification du rapport et de la polarit\u00e9 des transformateurs de courant int\u00e9gr\u00e9s (le cas \u00e9ch\u00e9ant)<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Pour tester le rapport de transformation et la polarit\u00e9 des transformateurs de courant (TC) int\u00e9gr\u00e9s et garantir une mesure correcte du courant ainsi qu&rsquo;un fonctionnement fiable du syst\u00e8me de protection du transformateur.<\/p>\n<p><img decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Built-in-Current-Transformer-Ratio-and-Polarity-Check-10.10.webp\" alt=\"Technicien utilisant un analyseur de TC pour la v\u00e9rification du rapport et de la polarit\u00e9 des transformateurs de courant int\u00e9gr\u00e9s sur un transformateur de distribution\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24153 size-full lazyload\"><noscript><img decoding=\"async\" src=\"https:\/\/omekpower.com\/fr\/wp-content\/uploads\/2026\/10\/Built-in-Current-Transformer-Ratio-and-Polarity-Check-10.10.webp\" alt=\"Technicien utilisant un analyseur de TC pour la v\u00e9rification du rapport et de la polarit\u00e9 des transformateurs de courant int\u00e9gr\u00e9s sur un transformateur de distribution\" width=\"630\" height=\"436\" class=\"alignnone wp-image-24153 size-full\"><\/noscript><\/p>\n<p><strong>\u00c9quipement d&rsquo;essai<\/strong> : Analyseur de TC<\/p>\n<p><strong>Proc\u00e9dure de base<\/strong> : injecter un courant connu dans le circuit primaire du TC ou utiliser le jeu d&rsquo;essai de TC appropri\u00e9. V\u00e9rifier le courant secondaire pour confirmer que le rapport du TC est correct ; v\u00e9rifier les connexions secondaires et les rep\u00e8res de polarit\u00e9 par rapport au sch\u00e9ma de c\u00e2blage.<\/p>\n<p><strong>Risques en cas d&rsquo;\u00e9chec<\/strong> : un rapport de TC incorrect peut entra\u00eener des lectures de courant erron\u00e9es, tandis qu&rsquo;une polarit\u00e9 incorrecte peut conduire \u00e0 des signaux de protection d\u00e9fectueux ou \u00e0 un fonctionnement inappropri\u00e9 des relais, emp\u00eachant la protection du transformateur.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"i-21\"><\/span>Comment lire un rapport d&rsquo;essai de routine de transformateur ?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Un rapport d&rsquo;essai de routine aide les acheteurs \u00e0 v\u00e9rifier si le transformateur est conforme aux sp\u00e9cifications techniques convenues et aux normes applicables.<\/p>\n<p>\u2705\ufe0f Param\u00e8tres nominaux vs valeurs mesur\u00e9es : comparer les r\u00e9sultats d&rsquo;essai mesur\u00e9s aux sp\u00e9cifications d&rsquo;achat requises pour la tension nominale, la puissance, le groupe vectoriel, etc.<\/p>\n<p>\u2705\ufe0f Normes applicables et limites d&rsquo;acceptation : s&rsquo;assurer que les r\u00e9sultats d&rsquo;essai sont conformes aux normes IEC appropri\u00e9es et aux limites d&rsquo;acceptation convenues.<\/p>\n<p>\u2705\ufe0f R\u00e9sultats d&rsquo;essai et enregistrements d&rsquo;anomalies : v\u00e9rifier les r\u00e9sultats conformes\/non conformes, les lectures anormales et toute action corrective ou enregistrement de nouvel essai.<\/p>\n<p>\u2705\ufe0f Liste de v\u00e9rification pour l&rsquo;acceptation client : v\u00e9rifier le num\u00e9ro de s\u00e9rie du transformateur, la couverture des essais requise, les r\u00e9sultats d&rsquo;essai et l&rsquo;approbation autoris\u00e9e avant livraison.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"i-22\"><\/span>Conclusion<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>L&rsquo;essai de routine du transformateur est un essai tr\u00e8s important pour confirmer la qualit\u00e9 du produit fabriqu\u00e9, identifier les d\u00e9fauts potentiels et pr\u00e9venir les risques en cours de fonctionnement avant la livraison. L&rsquo;examen des r\u00e9sultats d&rsquo;essai, \u00e0 l&rsquo;aune des normes applicables et des sp\u00e9cifications convenues, permettra \u00e0 l&rsquo;acheteur de s&rsquo;assurer de la conformit\u00e9 et de prendre une d\u00e9cision d&rsquo;acceptation \u00e9clair\u00e9e. Lors du choix d&rsquo;un fabricant de transformateurs, des protocoles d&rsquo;essai fiables peuvent contribuer \u00e0 garantir des performances durables et une fiabilit\u00e9 en cours de fonctionnement.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"i-23\"><\/span>Questions fr\u00e9quentes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>1. Qu&rsquo;est-ce qu&rsquo;un essai de routine de transformateur ?<\/strong><br \/>\nL&rsquo;essai de routine du transformateur est r\u00e9alis\u00e9 sur chaque transformateur pendant la production afin de s&rsquo;assurer que le transformateur satisfait aux performances \u00e9lectriques, au niveau d&rsquo;isolation et aux exigences sp\u00e9cifi\u00e9es. Les essais courants comprennent la r\u00e9sistance des enroulements, le rapport de tension, les pertes en charge, les pertes \u00e0 vide et les essais di\u00e9lectriques. Ces essais varient selon le type de transformateur et les normes auxquelles il doit se conformer.<\/p>\n<p><strong>2. Tous les transformateurs font-ils l&rsquo;objet d&rsquo;essais de routine obligatoires ?<\/strong><br \/>\nOui. Habituellement, chaque transformateur est soumis \u00e0 des essais de routine avant livraison afin de s&rsquo;assurer qu&rsquo;il est conforme aux normes et exigences techniques applicables.<\/p>\n<p><strong>3. Quelle norme IEC s&rsquo;applique aux transformateurs immerg\u00e9s dans l&rsquo;huile ?<\/strong><br \/>\nLes exigences g\u00e9n\u00e9rales relatives aux transformateurs de puissance, par exemple les essais de routine, sont donn\u00e9es dans l&rsquo;IEC 60076-1. Le niveau d&rsquo;isolation et les essais di\u00e9lectriques sont sp\u00e9cifi\u00e9s dans l&rsquo;IEC 60076-3.<\/p>\n<p><strong>4. Que se passe-t-il si un transformateur \u00e9choue \u00e0 un essai de routine ?<\/strong><br \/>\nLe fabricant doit identifier la cause de l&rsquo;\u00e9chec lors des essais de routine, corriger le d\u00e9faut et r\u00e9p\u00e9ter les essais. L&rsquo;autorisation de livrer le transformateur ne doit pas \u00eatre accord\u00e9e tant que le d\u00e9faut n&rsquo;a pas \u00e9t\u00e9 corrig\u00e9 et que les r\u00e9sultats d&rsquo;essai n\u00e9cessaires, conformes aux normes applicables et aux sp\u00e9cifications convenues, n&rsquo;ont pas \u00e9t\u00e9 obtenus.<\/p>\n<p><strong>5. Le fabricant fournira-t-il un rapport d&rsquo;essai de routine du transformateur ?<\/strong><br \/>\nOui. Les acheteurs peuvent demander un rapport d&rsquo;essai de routine du transformateur au fabricant avant la livraison. Les r\u00e9sultats d&rsquo;essai, les valeurs mesur\u00e9es et les crit\u00e8res d&rsquo;acceptation n\u00e9cessaires doivent \u00eatre fournis dans le rapport afin de garantir que le transformateur est conforme aux sp\u00e9cifications techniques convenues et aux normes applicables.<\/p>\n<p><strong>6. Comment tester un transformateur avec un multim\u00e8tre ?<\/strong><br \/>\nUn multim\u00e8tre peut \u00eatre utilis\u00e9 pour r\u00e9aliser des essais simples sur un transformateur, notamment la v\u00e9rification de l&rsquo;absence de circuit ouvert et de la continuit\u00e9 entre les enroulements. Il ne permet toutefois pas de confirmer tous les param\u00e8tres de performance ni la rigidit\u00e9 di\u00e9lectrique d&rsquo;un transformateur. Des \u00e9quipements d&rsquo;essai tels que le rapport de tension, la r\u00e9sistance des enroulements et la tenue di\u00e9lectrique sont n\u00e9cessaires. D\u00e9brancher le transformateur de la source d&rsquo;alimentation et s&rsquo;assurer qu&rsquo;il est hors tension avant l&rsquo;essai.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Les essais de routine avant livraison des transformateurs sont r\u00e9alis\u00e9s afin de v\u00e9rifier les performances \u00e9lectriques, de contr\u00f4ler l&rsquo;int\u00e9grit\u00e9 de l&rsquo;isolation et de rechercher d&rsquo;\u00e9ventuels d\u00e9fauts de fabrication. Ces essais sont effectu\u00e9s pour garantir que chaque transformateur est conforme aux exigences techniques sp\u00e9cifi\u00e9es, conform\u00e9ment aux normes IEC 60076 applicables. Ce guide couvre les types d&rsquo;essais de routine, les proc\u00e9dures, les objectifs, les crit\u00e8res d&rsquo;acceptation et les risques potentiels en cas d&rsquo;\u00e9chec des essais. Que sont les essais de routine ? Les essais de routine des transformateurs sont effectu\u00e9s sur chaque unit\u00e9 avant livraison afin de s&rsquo;assurer qu&rsquo;elle satisfait aux normes pertinentes et aux exigences techniques sp\u00e9cifiques. Selon le type et la conception du transformateur, les essais sont r\u00e9alis\u00e9s conform\u00e9ment aux normes IEC 60076 : IEC 60076-1, IEC 60076-3 et IEC 60076-11. Des proc\u00e9dures et des crit\u00e8res d&rsquo;acceptation sont d\u00e9finis pour chaque essai. Pourquoi les essais de routine sont-ils importants ? [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":26214,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-26213","post","type-post","status-publish","format-standard","has-post-thumbnail","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/posts\/26213","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/comments?post=26213"}],"version-history":[{"count":1,"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/posts\/26213\/revisions"}],"predecessor-version":[{"id":26234,"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/posts\/26213\/revisions\/26234"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/media\/26214"}],"wp:attachment":[{"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/media?parent=26213"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/categories?post=26213"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/omekpower.com\/fr\/wp-json\/wp\/v2\/tags?post=26213"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}